Analog input function selector

The reference processing method is selected by way of the function selector. The default setting is the function RERV(-2), with which the reference input +/-10 V is evaluated referred to user units.

The parameters are initialized only after the control has been re-enabled or by a device restart.

The selection TLIM(-4) to REFV(-2) is reserved for the analog input function. The other settings can be used for the function as a digital input.


Bild: Analog input function selector (-5) to (-1)


Settings for the analog input

P. no.

Parameter name

Setting

Function
P 0109/
P 0110
MPRO_INPUT_FS_ISA00/ISA01 Reference selector for the analog inputs
(-5) Not defined Not defined
(-4) TLIM(-4)

Torque scaling:
0 to 10 V corresponds to 0-100% of the maximum set torque. The backlash is not effective for these functions.

(-3) OVR(-3) Scaling of the parameterized travel speed in positioning
(0 to 10 V corresponds to 0 – 100%). The override is recorded directly after the analog filter. The backlash is not effective for these functions!
(-2) REFV(-2) Reference input +/-10 V referred to user units.

Tabelle: Reference selector