For channels 1 and 3 one gear ratio each can be set for the encoder. Using the gear ratio permits adaptation of an encoder mounted on the load side to the motor shaft. For encoder channel 2 it is to be assumed that the resolver is always mounted on the motor shaft. The adjustment range is therefore limited to (+1) or (-1), meaning the encoder signal can only be inverted.
Parameters
P. no. | Designation | Function |
---|---|---|
P 0510 | ENC_CH1_Num | Denominator of channel 1 |
P 0511 | ENC_CH1_Denom | Numerator of channel 1 |
P 0512 | ENC_CH2_Num | Denominator of channel 2 |
P 0513 | ENC_CH2_Denom | Numerator of channel 2 |
P 0514 | ENC_CH3_Num | Denominator of channel 3 |
P 0515 | ENC_CH3_Denom |
Numerator of channel 3 |
Tabelle: Parameters for encoder transmission ratio