Cyclic encoder evaluation via channel 1 (SinCos X7)
On channel 1 (SinCos, X7) digital encoders can be cyclically read. The selection is made via P 0505 ENC_CH1_Sel. The number of MT/ST bits is set via parameters P 0543 and P 0544.
Parameters
P. no. |
Parameter name/ Setting |
Function |
---|---|---|
P 0505 | ENC_CH1_SEL | Encoder selection for channel 1 |
(0) | OFF (0) | Function disabled |
(1) | SINCOS(1) | SinCos encoder |
(2) | SSI(2) | Digital SSI encoder |
(3) | TTL(3) | TTL encoder |
(4) | EnDat(4) | Digital EnDat 2.2 |
(5) | HALL(5) | Digital Hall sensor |
P 0543 | ENC_CH1_MultiT | Number of multi-turn bits |
P 0544 | ENC_CH1_SingleT | Number of single-turn bits |
P 0553 | ENC_CH1_PeriodLen | Length of a signal period |
P 0554 | ENC_CH1_DigitalResolution | Digital resolution (length of an increment) |
P 0616 | ENC_CH1_CycleCount | Sampling time (x 125 µs) |
Tabelle: Cyclic evaluation of digital encoders
NOTE: As encoders with different protocol modes exist (with/without error bit, parity bit, etc.), LTi DRiVES GmbH should be consulted before using them. |
Copyright © LTi DRiVES GmbH, Januar 2013, ID-Nr.: 0842.26B.1-00 DE