[DIALOG] Pre: The device is in an error state!\n\n Post: \n\nPlease press "Continue" button to reset error NOW or "Abort" to reset \nerror LATER [E1] 1: Error: CPU\n\nCause:\n Error due to defective control unit or incorrect software version\n\nRemedy:\n Switch device off/on.\n Please contact Your service provider if this error occurs again. 8: Error: CPU\n\nCause:\n Error in self-test:\n Parameter initialization failed due to faulty parameter description\n\nRemedy:\n 1. Switch device off/on.\n 2. Please contact Your service provider if this error occurs again. 17: Error: CPU\n\nCause:\n RAM area for scope functionality inadequate\n\nRemedy:\n Please contact Your service provider if this error occurs again. 30: Error: CPU\n\nCause:\n Program memory data faulty (detected by selftest during device start)\n\nRemedy:\n Please contact Your service provider if this error occurs again. 39: Error: CPU\n\nCause:\n Program memory data faulty (detected by online test)\n\nRemedy:\n Please contact Your service provider if this error occurs again. [E2] 1: Error: OFF\n\nCause:\n DC-link voltage too low (also indicated on normal power-off)\n\nRemedy:\n Rectify power failure or connect higher mains voltage [E3] 1: Error: OC\n\nCause:\n Current overload due to\n 1. Incorrectly set parameters\n 2. Short, earth fault or insulation fault\n 3. Internal device defect\n\nRemedy:\n 1. Check parameters of control circuits\n 2. Check installation\n 3. Please contact Your service provider if this error occurs again. 19: Error: OC\n\nCause:\n max. current space vector exceeded\n 1. Incorrectly set parameters\n 2. Short, earth fault or insulation fault\n 3. Internal device defect\n\nRemedy:\n 1. Check parameters of control circuits\n 2. check installation\n 3. Please contact Your service provider if this error occurs again. 34: Error: OC\n\nCause:\n allowed current limit exceeded\n 1. Incorrectly set parameters\n 2. Short, earth fault or insulation fault\n 3. Internal device defect\n\nRemedy:\n 1. Check parameters of control circuits\n 2. Check installation\n 3. Please contact Your service provider if this error occurs again. 35: Error: OC\n\nCause:\n Overcurrent at test of wiring\n Remedy:\n Check wiring in inverter output 109: Error: OC\n\nCause:\n Measuring range overflow of ADC of current measurement\n 1. Incorrectly set parameters\n 2. Short, earth fault or insulation fault\n 3. Internal device defect\n\nRemedy:\n 1. Check parameters of control circuits\n 2. Check installation\n 3. Please contact Your service provider if this error occurs again. [E4] 1: Error: OV\n\nCause:\n Voltage overload due to\n 1. Braking chopper overload (braked too long or too much)\n 2. Mains power overload\n\nRemedy:\n 1. Set DECR ramp parameter slower (_REF), use braking resistor or chopper\n 2. Adjust mains voltage [E5] 1: Error: OLM\n\nCause:\n Ixt shut-off to protect motor (permissible current/time area exceeded)\n\nRemedy:\n 1. Reduce load\n 2. Use a higher-powered motor [E6] 1: Error: OLI\n\nCause:\n I^2xt shut-off to protect power stage (permissible current/time area exceeded)\n\nRemedy:\n Reduce load [E7] 18: Error: OTM\n\nCause:\n Motor overheating (PTC in motor tripped) due to\n 1. PTC not connected\n 2. Motor overload\n\nRemedy:\n 1. Allow motor to cool down\n 2. Connect PTC or jumper terminals with 100 Ohm\n 3. Use a higher-powered motor [E8] 31: Error: OTI\n\nCause:\n Power stage overheating due to\n 1. Ambient temperature too high\n 2. Load too high (power stage or braking chopper)\n\nRemedy:\n 1. Improve ventilation\n 2. Use a higher-powered device\n 32: Error: OTI\n\nCause:\n Overheating in device interior due to\n 1. Ambient temperature too high\n 2. Load too high (power stage or braking chopper)\n\nRemedy:\n 1. Improve ventilation\n 2. Use a higher-powered device\n [E9] 1: Error: PLS\n\nCause:\n Plausibility check detected invalid parameter or impermissible program sequence\n\nRemedy:\n Please contact Your service provider if this error occurs again. 6: Error: PLS\n\nCause:\n Unknown switching frequency on initialization of power stage protection\n\nRemedy:\n Please contact Your service provider if this error occurs again. 8: Error: PLS\n\nCause:\n Unable to initialize parameter list in device startup phase.\n KP200 may display number of faulty parameter at top left.\n\nRemedy: Reset device via:\n 1. Set parameter PROG=1.\n 2. Switch off device, hold down KP200 Up and Down key\n and switch device back on. KP200 indicates "RESET" 9: Error: PLS\n\nCause:\n Plausibility check detected invalid parameter object (incorrect data type\n or incorrect data length)\n\nRemedy:\n Please contact Your service provider if this error occurs again.. 10: Error: PLS\n\nCause:\n No readable parameter exists at the current user level\n or parameter access error via KP200\n\nRemedy:\n Please contact Your service provider if this error occurs again.. 13: Error: PLS\n\nCause:\n Both slots assigned the same module\n\nRemedy:\n Remove a module. 20: Error: PLS\n\nCause:\n Error in auto-tuning\n\nRemedy:\n 1. Check match of motor rating plate data with corresponding motor parameters \n and restart auto-tuning.\n 2. Please contact Your service provider if this error occurs again. 101: Error: PLS\n\nCause:\n Unknown switching frequency in initialization of PWM\n\nRemedy:\n Please contact Your service provider if this error occurs again. [E10] 0: Error: PAR\n\nCause:\n Invalid parameter setting\n\nRemedy:\n Correct parameter setting or reset device to factory setting 2: Error: PAR\n\nCause:\n Parameter FMINx greater than parameter min (FMAXx, FMXAx, FABS) or error \n in initialization of current-controlled startup\n\nRemedy:\n Set FMINx < min (FMAXx, FMXAx, FABS) 7: Error: PAR\n\nCause:\n The value of a parameter after the device startup phase\n is outside its value range.\n\nRemedy:\n Parameter 423-ERPAR contains the number of the faulty parameter whose setting needs to be checked. 8: Error: PAR\n\nCause:\n Error in first initialization of parameter list.\n A parameter could not be set to factory setting\n\nRemedy:\n Parameter 423-ERPAR contains the number of the faulty parameter whose setting needs to be checked. 13: Error: PAR\n\nCause:\n The combination of the settings of the function selector for one of the\n analog inputs and the reference selector conflict\n\nRemedy:\n Check and change setting 16: Error: PAR\n\nCause:\n The setting of parameter FOSA0 (function selector output OSA0)\n is outside its value range\n\nRemedy:\n Check and change setting 100: Error: PAR\n\nCause:\n Error in controller initialization\n\nRemedy:\n Check setting of controller and motor parameters.\n Restart auto-tuning as necessary. 101: Error: PAR\n\nCause:\n Error in initialization of PWM\n\nRemedy:\n Please contact Your service provider if this error occurs again. 102: Error: PAR\n\nCause:\n Error in encoder evaluation\n\nRemedy:\n Please contact Your service provider if this error occurs again. 104: Error: PAR\n\nCause:\n Error in initialization of voltage frequency control\n\nRemedy:\n Please contact Your service provider if this error occurs again. 105: Error: PAR\n\nCause:\n Error in initialization of actual value recording\n\nRemedy:\n Please contact Your service provider if this error occurs again. 106: Error: PAR\n\nCause:\n Two interpolation points of the V/F characteristic have the same frequency\n\nRemedy:\n Change setting 107: Error: PAR\n\nCause:\n Slope between two interpolation points for the V/F characteristic is too large\n\nRemedy:\n Change setting 108: Error: PAR\n\nCause:\n Error in initialization of SFC due to inappropriate \n motor and controller parameter setting\n\nRemedy:\n Check controller and motor settings and restart auto-tuning as necessary. [E11] 0: Error: FLT\n\nCause:\n General error in floating point calculation\n\nRemedy:\n Please contact Your service provider if this error occurs again. [E12] 6: Error: PWR\n\nCause:\n Power pack not correctly identified\n\nRemedy:\n 1. Return device\n 2. Please contact Your service provider if this error occurs again. 8: Error: PWR\n\nCause:\n Error at first initializing of parameter list\n\nRemedy:\n 1. Return device\n 2. Please contact Your service provider if this error occurs again. [E13] 1: Error: EXT\n\nCause:\n Error in an external device\n\nRemedy:\n Rectify error in external device [E15] 150: Error: OP1\n\nCause:\n Error in module at option slot 1\n\nRemedy:\n 1. Check module and identifier\n 2. Please contact Your service provider if this error occurs again. 151: Error: OP1\n\nCause:\n Error on option 1: BUS-OFF state detected\n\nRemedy:\n Check module contacting. If the error still occurs after switching\n off/on the device or module is defective. 152: Error: OP1\n\nCause:\n Error on option 1: Unable to send transmit protocol.\n\nRemedy:\n Check module contacting. If the error still occurs after switching\n off/on the device or module is defective. 153: Error: OP1\n\nCause:\n Error on option 1: Module no longer responding\n\nRemedy:\n Check module contacting. If the error still occurs after switching\n off/on the device or module is defective. 154: Error: OP1\n\nCause:\n Error on option 1: Module signals error\n\nRemedy:\n Check module contacting. If the error still occurs after switching\n off/on the device or module is defective. 155: Error: OP2\n\nCause:\n Error on option 1: Initializing error\n\nRemedy:\n Check module contacting. If the error still occurs after switching/n off/on the device or module is defective. [E16] 170: Error: OP2\n\nCause:\n Error in module at option slot 2\n\nRemedy:\n 1. Check module and identifier\n 2. Please contact Your service provider if this error occurs again. 171: Error: OP2\n\nCause:\n Error on option 2: BUS-OFF state detected\n\nRemedy:\n Check module contacting. If the error still occurs after switching\n off/on the device or module is defective. 172: Error: OP2\n\nCause:\n Error on option 2: Unable to send transmit protocol.\n\nRemedy:\n Check module contacting. If the error still occurs after switching\n off/on the device or module is defective. 173: Error: OP2\n\nCause:\n Error on option 2: Module no longer responding\n\nRemedy:\n Check module contacting. If the error still occurs after switching\n off/on the device or module is defective. 174: Error: OP2\n\nCause:\n Error on option 2: Module signals error\n\nRemedy:\n Check module contacting. If the error still occurs after switching\n off/on the device or module is defective. 175: Error: OP2\n\nCause:\n Error on option 2: Initializing error\n\nRemedy:\n Check module contacting. If the error still occurs after switching\n off/on the device or module is defective. [E17] 0: Error: WRN\n\nCause:\n Device temperature above warning threshold parameter\n\nRemedy:\n 1. Check warning threshold\n 2. Improve ventilation\n 3. Use a higher-powered device 1: Error: WRN\n\nCause:\n Interior temperature above warning threshold parameter\n\nRemedy:\n 1. Check warning threshold\n 2. Improve ventilation\n 3. Use a higher-powered device 2: Error: WRN\n\nCause:\n Motor temperature above warning threshold parameter\n\nRemedy:\n 1. Check warning threshold\n 2. Allow motor to cool down\n 3. Connect PTC or jumper terminals with 100 Ohm\n 4. Use a higher-powered motor 3: Error: WRN\n\nCause:\n DC-link voltage above warning threshold parameter for voltage overload\n\nRemedy:\n 1. Check warning threshold\n 2. Set DECR ramp parameter slower (_REF), use braking resistor or chopper\n 3. Adjust mains voltage 4: Error: WRN\n\nCause:\n DC-link voltage below warning threshold parameter for undervoltage\n\nRemedy:\n 1. Check warning threshold\n 2. Rectify power failure or connect a higher mains voltage 5: Error: WRN\n\nCause:\n Output frequency above warning threshold parameter\n\nRemedy:\n 1. Check warning threshold\n 2. Check settings for reference generation\n 3. Set reference limitation parameters appropriately 6: Error: WRN\n\nCause:\n Apparent current above warning threshold parameter\n\nRemedy:\n 1. Check warning threshold\n 2. Reduce load 7: Error: WRN\n\nCause:\n I^2xt integrator (motor protection) above warning threshold parameter\n\nRemedy:\n 1. Check warning threshold\n 2. Reduce load\n 3. Use a higher-powered motor 8: Error: WRN\n\nUrsache:\n Reference coupling\n\nRemedy:\n 1. Check warning threshold 9: Error: WRN\n\nUrsache:\n Ixt-integrator (motor protection) started\n\nRemedy:\n 1. Check warning threshold [E18] 11: Error: SIO\n\nCause:\n Watchdog for monitoring communication over LustBus tripped\n\nRemedy:\n 1. Check connection\n 2. Check bus master or increase parameter SWDGT [E19] 3: Error: EEP\n\nCause:\n Error accessing parameter memory\n\nRemedy:\n 1. switch device off/on\n 2. If device remains in error state after switch on, reset it to\n factory setting and switch off/on again.\n 3. Please contact Your service provider if this error occurs again. 6: Error: EEP\n\nCause:\n Error at initializing of hardware\n\nRemedy:\n 1. Switch device off/on\n 2. If device remains in error state after switch on, reset it to\n factory setting and switch off/on again.\n 3. Please contact Your service provider if this error occurs again. 9: Error: EEP\n\nCause:\n Error at initializing of an element function of a parameter object\n\nRemedy:\n 1. Please contact Your service provider if this error occurs again. 18: Error: EEP\n\nCause:\n Error at initializing of automatic parameter data out of the EEPROM\n\nRemedy:\n 1. Please contact Your service provider if this error occurs again. [E20] 1: Error: WBK\n\nCause:\n Possible wire break at input ISA01. Current less than 4mA in parameter setting to 4-20mA\n\nRemedy:\n Check wiring of input ISA01 [E21] 20: Error: SC\n\nCause:\n Error in auto-tuning\n\nRemedy:\n 1. Check motor wiring and repeat procedure.\n 2. Please contact Your service provider if this error occurs again. 21: Error: SC\n\nCause:\n Error in auto-tuning. Motor not connected or not properly connected\n\nRemedy:\n 1. Check motor wiring and repeat procedure.\n 2. Please contact Your service provider if this error occurs again. 22: Error: SC\n\nCause:\n Auto-tuning is only suitable for asynchronous machines.\n\n\nRemedy:\n Set parameter 153-CFMOT to ASM if an appropriate motor is used, and repeat auto-tuning. 23: Error: SC\n\nCause:\n Auto-tuning is unable to identify the connected motor correctly.\n\n\nRemedy:\n 1. Get motor parameters from manufacturer and enter manually\n 2. If possible use a different motor [E22] 1: Error: PF\n\nCause:\n Error in power failure bridging: DC-link voltage not restored\n within the time parameter (343-PFTIM).\n\nRemedy:\n 1. Check mains power supply [E23] 0: Error: RM\n\nCause:\n Error in activation of an application data set\n\nRemedy:\n 1. The error location number details the faulty parameter.\n 2. Please contact Your service provider if this error occurs again. [E24] 1: Error: FDG\n\nCause:\n Transmissions error in reference coupling\n\nRemedy:\n 1. Check connection [E25] 1: Error: LSW\n\nCause:\n Limit switches confused\n\nRemedy:\n 1. Correct installation [E26] 1: Error: OL5\n\nCause:\n Ixt-switch-off under 5 Hz to protect the final stage\n (Exceeding the allowed current-time-area)\n\nRemedy:\n Reduce load [E27] 1: Error: PIC\n\nCause:\n Exceeding the control deviation\n (Error in control circuit)\n\nRemedy:\n Check control circuit [E28] 1: Error: FLW\n\nCause:\n Exceeding the max. frequency deviation at FOR \n (overdone acceleration/braking)\n\nRemedy:\n Reduce ramps