[DIALOG] Pre: Error or warning occured!\n\n Post: \n\nPress button\n "Continue", to reset error NOW or \n "Cancel", to reset error LATER (e.g. button "Reset"). \n\nNote:\n Errors with the a.m. reaction "RESET" can only be confirmed by\n switching off/on the device! [E1] 0: Error: CPU\nReaction: RESET\n\nCause:\n Processor defect or incorrect software version\n\nRemedy:\n 1. Switch device off/on.\n 2. Please contact your service provider if this error occurs again. 6: Error: CPU\nReaction: RESET\n\nCause:\n Error in Cache-memory of serial EEPROM\n\nRemedy:\n 1. Switch device off/on.\n 2. Please contact your service provider if this error occurs again. 8: Error: CPU\nReaction: RESET\n\nCause:\n Error in self test:\n Parameter initialization failed due to faulty parameter description\n\nRemedy:\n 1. Switch device off/on.\n 2. Please contact your service provider if this error occurs again. 17: Error: CPU\nReaction: RESET\n\nCause:\n RAM area for scope functionality indequate\n\nRemedy:\n 1. Switch device off/on.\n 2. Please contact your service provider if this error occurs again. 44: Error: CPU\nReaction: RESET\n\nCause:\n Timeout at parameter identification\n\nRemedy:\n 1. Switch device off/on.\n 2. Please contact your service provider if this error occurs again. 55: Error: CPU\nReaction: RESET\n\nCause:\n Program memory data faulty\n\nRemedy:\n 1. Switch device off/on.\n 2. Please contact your service provider if this error occurs again. [E2] 1: Error: OFF\n\nCause:\n DC-link voltage < 212/425 V (also indicated at normal power-off)\n\nRemedy:\n Rectify power failure of connect higer mains voltage [E3] 0: Error: OC\n\nCause:\n Current overload due to\n 1. Incorrect parameter setting\n 2. Short, earth fault or insulation fault\n 3. Internal device defect\n\nRemedy:\n 1. Check parameters of control circuits\n 2. Check installation 19: Error: OC\n\nCause:\n Power stage protection initiated.\n Maximum allowed motor power exceeded\n depends on DC-link voltage and heat sink temperature.\n\nRemedy:\n 1. Check operating conditions of device\n 2. Reduce load 34: Error: OC\n\nCause:\n Ixt-shut-off below 5 Hz to protect power stage\n (permissible current/time area exceeded)\n\nRemedy:\n Reduce load 35: Error: OC\n\nCause:\n Current overload shut-off after wiring test\n Detected short, earth fault or insulation fault\n\nRemedy:\n 1. Check installation\n 2. Check motor insulation 41: Error: OC\n\nCause:\n Current overload due to hardware shut-off\n 1. Incorrect parameter setting\n 2. Short, earth fault or insulation fault during operation\n 3. Internal device defect\n\nRemedy:\n 1. Check parameter of control circuits\n 2. Check installation\n 3. Please contact your service provider if this error occurs again. [E4] 1: Error: OV\n\nCause:\n Voltage overload due to\n 1. Braking chopper overload (braked too long or too much)\n 2. Mains poer overload\n\nRemedy:\n 1. Set DECR ramp parameter lower, use ext. braking resistor or chopper\n 2. Adjust mains voltage [E5] 1: Error: OLM\n\Cause:\n I^2xt-shut-off to protect motor\n (permissible current/time area exceeded)\n\nRemedy:\n 1. Reduce load\n 2. Use higher-powered motor [E6] 1: Error: OLI\n\nCause:\n I^2xt-shut-off to protect power stage\n (permissible current/time area exceeded)\n\nRemedy:\n Reduce load [E7] 1: Error: OTM\n\nCause:\n Overheating motor (PTC in motor tripped) due to\n 1. PTC not connected or incorrect parameter setting\n 2. Overload of motor\n\nRemedy:\n 1. Allow motor to cool down\n 2. Connect PTC or check adjusment\n 3. Use a higher-powered motor [E8] 31: Error: OTI\n\nCause:\n Overheating of power stage due to\n 1. Ambient temperature too high\n 2. Load too high (power stage or bracking chopper)\n\nRemedy:\n 1. Improve ventilation\n 2. Use a higher-powered device\n 32: Error: OTI\n\nCause:\n Overheating in device interior due to\n 1. Ambient temperature too high\n 2. Load too high (power stage or braking chopper)\n\nRemedy:\n 1. Improve ventilation\n 2. Use a higher-powered device\n [E9] 1: Error: PLS\nReaction: RESET\n\nCause:\n Plausibility check detected invalid program sequence\n\nRemedy:\n 1. Switch device off/on.\n 2. Please contact your service provider if this error occurs again. 4: Error: PLS\nReaction: RESET\n\nCause:\n Invalid sequence on controller initializing\n\nRemedy:\n 1. Switch device off/on.\n 2. Please contact your service provider if this error occurs again. 6: Error: PLS\nReaction: RESET\n\nCause:\n Unknown switching frequency on initializing power stage protection\n\nRemedy:\n Please contact your service provider if this error occurs again. 8: Error: PLS\nReaction: RESET\n\nCause:\n Unable to initialize parameter list in device start-up phase.\n KP200 (at top left) or indication of parameter 423-ERPAR\n or the number of the faulty parameters.\n\nRemedy via reset of the device by means of:\n 1. DriveManager - active device -> reset to factory setting.\n 2. Switch-off device, hold down KP200 up and down key\n and switch-on deviced again. KP200 indicates "RESET" 9: Error: PLS\nReaction: RESET\n\nCause:\n Plausibility check detected invalid parameter object (incorrect data type\n or incorrect data length)\n\nRemedy:\n 1. Switch device off/on.\n 2. Please contact your service provider if this error occurs again. 10: Error: PLS\nReaction: RESET\n\nCause:\n No readable parameter exists at the current user level\n or parameter access error via KP200\n\nRemedy:\n 1. Switch device off/on.\n 2. Please contact your service provider if this error occurs again. 13: Error: PLS\nReaction: RESET\n\nCause:\n Both slots assigned the same module\n\nRemedy:\n 1. Remove a module.\n 2. Switch device off/on. 20: Error: PLS\nReaction: RESET\n\nCause:\n Error in auto-tuning\n\nRemedy:\n 1. Check match of motor rating plate data with corresponding motor parameters \n and re-start test and auto-tuning.\n 2. Please contact your service provider if this error occurs again. 33: Error: PLS\nReaction: RESET\n\nCause:\n Selected pre-setting does not converge with the parameter list\n\nRemedy\n 1. Install suitable firmware\n 2. Use other pre-setting\n 3. Please contact your service provider if this error occurs again. 48: Error: PLS\nReaction: RESET\n\nCause:\n Invalid sequence on macro processing\n\nRemedy:\n 1. Switch device off/on.\n 2. Please contact your service provider if this error occurs again. 100: Error: PLS\nReaction: RESET\n\nCause:\n Internal parameter access error on controller initializing\n\nRemedy:\n 1. Switch device off/on.\n 2. Please contact your service provider if this error occurs again. 101: Error: PLS\nReaction: RESET\n\nCause:\n No support to set lines per revolution of encoder\n\nRemedy:\n 1. Correction of lines per revolution (Parameter 432-ECLNC) 102: Error: PLS\nReaction: RESET\n\nCause:\n Unknown switching frequency on initialiszing PWM\n\nRemedy:\n 1. Switch device off/on.\n 2. Please contact your service provider if this error occurs again. 121: Error: PLS\nReaction: RESET\n\nCause:\n No support to set lines per revolution of encoder\n\nRemedy:\n 1. Correction of lines per revolution (Parameter 474-EC2LN) 122: Error: PLS\nReaction: RESET\n\nCause:\n Incorrect configuration of connection X5\n (encoder simulation, encoder)\n\nRemedy:\n 1. Check adjustment of encoder or encoder simulation.\n 2. Please contact your service provider if this error occurs again. 250: Error: PLS\nReaction: RESET\n\nCause:\n Incorrect sequence of marker position of cam circuit\n\nRemedy:\n Set the positions in ascending sequency [E10] 0: Error: PAR\n\nCause:\n Invalid parameter setting\n\nRemedy:\n Correction of parameter setting or reset device to factory settin 7: Error: PAR\n\nCause:\n Value of one parameter is after start-up phase\n outside its value range.\n\nRemedy:\n Parameter 423-ERPAR contains the number of the faulty parameters, whose setting needs to be checked.\n 1. Switch device off/on\n 2. Correct source data set (offline) and store in device. 8: Error: PAR\n\nCause:\n Error in first initialization of parameter list.\n One parameter cannot reset to factory setting\n\nRemedy:\n Parameter 423-ERPAR contains the number of the faulty parameters, whose setting needs to be checked.\n 1. Switch device off/on\n 2. Please contact your service provider if this error occurs again. 9: Error: PAR\n\nCause:\n Error in initialization of a parameter with\n its stored adjustment.\n\nRemedy:\n Parameter 423-ERPAR contains the number of the faulty parameters, whose setting needs to be checked.\n 1. Switch device off/on\n 2. If this error occurs again, reset device to factory setting\n and store adjustment in device. 13: Error: PAR\n\nCause:\n The combination of the settings of the function selector\n for one of the analog inputs \n \nRemedy:\n Check and change adjustment 16: Error: PAR\n\nCause:\n Setting of parameter FOSA0 (function selector output OSA0)\n is outside its value range\n\nRemedy:\n Check and change adjustment 100: Error: PAR\n\nCause:\n Error in controller initialization\n\nRemedy:\n Check and change setting of control and motor parameters 101: Error: PAR\n\nCause:\n Error in initialization of encoder\n Resolver: Invalid number of pairs of poles for motor parameters\n\nRemedy:\n Check and change setting of encoder 102: Error: PAR\n\nCause:\n Error in initialization of modulation\n\nRemedy:\n Check and change setting of modulation 103: Error: PAR\n\nCause:\n Error in initialization of current control\n\nRemedy:\n Check and change setting of control and motor parameter 104: Error: PAR\n\nCause:\n Error in initializiation of speed calculation\n\nRemedy:\n Check and change setting of encoder 105: Error: PAR\n\nCause:\n Error in initialization of control task list\n\nRemedy:\n Check and change setting of control 106: Error: PAR\n\nCause:\n Error in initialization of torque calculation\n\nRemedy:\n Check and change setting of control and motor parameter 107: Error: PAR\n\nCause:\n Error in initialization of current models\n\nRemedy:\n Check and change setting of control and motor parameter 108: Error: PAR\n\nCause:\n Error in initialization of speed controller\n\nRemedy:\n Check and change setting of control and motor parameter 109: Error: PAR\n\nCause:\n Error in initialization of position calculation\n\nRemedy:\n Check and change setting of control and motor parameter 110: Error: PAR\n\nCause:\n Error in initialization of position control\n\nRemedy:\n Check and change setting of control and motor parameter 111: Error: PAR\n\nCause:\n Error in initialization of speed pilot control\n\nRemedy:\n Check and change setting of control and motor parameter 112: Error: PAR\n\nCause:\n Error in initialization of flux control\n\nRemedy:\n Check and change setting of control and motor parameter 113: Error: PAR\n\nCause:\n Error in initialization of voltage control\n\nRemedy:\n Check and change setting of control and motor parameter 114: Error: PAR\n\nCause:\n Error in initialization of voltage control\n\nRemedy:\n Check and change setting of control and motor parameter 115: Error: PAR\n\nCause:\n Error in initialization of flux control in FWR\n\nRemedy:\n Check and change setting of control and motor parameter 116: Error: PAR\n\nCause:\n Error in initialization of v/f characteristic line\n\nRemedy:\n Check and change setting of control and motor parameter 117: Error: PAR\n\nCause:\n Error in initialization of current/-voltage models\n\nRemedy:\n Check and change setting of control and motor parameter 118: Error: PAR\n\nCause:\n Error in initialization of control\n\nRemedy:\n Check and change setting of control and motor parameter 119: Error: PAR\n\nCause:\n Error in initialization of control\n\nRemedy:\n Check and change setting of control and motor parameter 120: Error: PAR\n\nCause:\n Error in initialization of encoder simulation\n\nRemedy:\n Check and change setting of connection configuraiton 121: Error: PAR\n\nCause:\n Error in initialization of connection X5\n (encoder/encoder simulation)\n\nRemedy:\n Check and change setting of connection configuration 122: Error: PAR\n\nCause:\n Error in initialization of connection X5\n (encoder/encoder simulation)\n\nRemedy:\n Check and change setting of connection configuration [E11] 0: Error: FLT\n\nCause:\n General error in floating point calculation\n\nRemedy:\n 1. Switch device off/on.\n 2. Please contact your service provider if this error occurs again. [E12] 6: Error: PWR\nReaction: RESET\n\nCause:\n Power pack not correctly identified\n\nRemedy:\n 1. Switch device off/on.\n 2. Please contact your service provider if this error occurs again. [E13] 1: Error: EXT\n\nCause:\n Error in external device\n\nRemedy:\n Rectify error in external device [E14] 0: Error: USR\n\nCause:\n Error in execution of a customer specific software function\n\nRemedy:\n 1. Check software version.\n 2. Please contact your service provider if this error occurs again. [E15] 150: Error: OP1\n\nCause:\n Error in module at option slot 1\n\nRemedy:\n 1. Check module and identifier\n 2. Please contact your service provider if this error occurs again. 151: Error: OP1\n\nCause:\n Error on option 1: BUS-OFF-condition identified\n\nRemedy:\n Check module contacting. If the error still occurs after switching\n off/on the device or module is defect. 152: Error: OP1\n\nCause:\n Error on option 1: Unable to send transmit-protocol.\n\nRemedy:\n Check module contacting. If the error still occurs after switching\n off/on the device or module is defect. 153: Error: OP1\n\nCause:\n Error on option 1: Module not longer responding\n\nRemedy:\n Check module contacting. If the error still occurs after switching\n off/on the device or module is defect. 154: Error: OP1\n\nCause:\n Error on option 1: Module signals error\n\nRemedy:\n Check module contacting. If the error still occurs after switching\n off/on the device or module is defect. [E16] 170: Error: OP2\n\nCause:\n Error in module at option slot 2\n\nRemedy:\n 1. Check module and identifier\n 2. Please contact your service provider if this error occurs again. 171: Error: OP2\n\nCause:\n Error on option 2: BUS-OFF-condition identified\n\nRemedy:\n Check module contacting. If the error still occurs after switching\n off/on the device or module is defect. 172: Error: OP2\n\nCause:\n Error on option 2: Unable to send transmit-protocol.\n\nRemedy:\n Check module contacting. If the error still occurs after switching\n off/on the device or module is defect. 173: Error: OP2\n\nCause:\n Error on option 2: Module not longer responding\n\nRemedy:\n Check module contacting. If the error still occurs after switching\n off/on the device or module is defect. 174: Error: OP2\n\nCause:\n Error on option 2: Module signals error\n\nRemedy:\n Check module contacting. If the error still occurs after switching,\n off/on the device or module is defect. [E18] 11: Error: SIO\n\nCause:\n Watchdog for control of communication via LustBus tripped\n\nRemedy:\n 1.Check connection\n 2. Check busmaster or increase parameter SWDGT \n 3. Switch-off control (factory setting) with parameter SWDGT = 0 [E19] 0: Error: EEP\nReaction: RESET\n\nCause:\n Error accessing parameter memory\n\nRemedy:\n 1. Switch device off/on\n 2. Please contact your service provider if this error occurs again. 3: Error: EEP\nReaction: RESET\n\nCause:\n Error in writing the parameter memory\n\nRemedy:\n 1. Switch device off/on\n 2. Please contact your service provider if this error occurs again. 6: Error: EEP\nReaction: RESET\n\nCause:\n Error in reading the parameter memory during start-up phase\n\nRemedy:\n 1. Switch device off/on 2. Please contact your service provider if this error occurs again. 9: Error: EEP\nReaction: RESET\n\nCause:\n Error in writing a string parameter in parameter memory\n\nRemedy:\n 1. Switch device off/on\n 2. If this error occurs again, reset device to factory setting.\n 3. Please contact your service provider if this error occurs again. 18: Error: EEP\nReaction: RESET\n\nCause:\n Error of checksum in initialization of autosave-parameter\n\nRemedy:\n 1. Switch device off/on. Error will automatically be corrected.\n 2. Please contact your service provider if this error occurs again. 38: Error: EEP\nReaction: RESET\n\nCause:\n Error of checksum in initailization of device setting\n\nRemedy:\n 1. Switch device off/on\n 2. If this error occurs again, reset device to factory setting.\n and store adjustment in the device. [E21] 20: Error: SC\n\nCause:\n Error in auto-tuning\n\nRemedy:\n 1. Check motor wiring and repeat procedure.\n 2. Please contact Your service provider if this error occurs again. 21: Error: SC\n\nCause:\n Error in auto-tuning. Motor not connected or not properly connected\n\nRemedy:\n 1. Check motor wiring and repeat procedure.\n 2. Please contact Your service provider if this error occurs again. 22: Error: SC\n\nCause:\n Auto-tuning is only suitable for asynchronous machines.\n\n\nRemedy:\n Set parameter 153-CFMOT to ASM if an appropriate motor is used, and repeat auto-tuning. 23: Error: SC\n\nCause:\n Auto-tuning is unable to identify the connected motor correctly.\n\n\nRemedy:\n 1. Get motor parameters from manufacturer and enter manually\n 2. If possible use a different motor [E25] 47: Error: HWE\n\nCause:\n Hardware endswitch interchanged\n\nRemedy:\n Correction of endswitch wiring, or configuration\n of inputs of CDD3000 according to suppresion. [E26] 1: Error: OL5\n\nCause:\n Ixt-Shut-off below 5 Hz to protect power stage\n (Allowed current/time area exceeded)\n\nRemedy:\n Reduce load [E30] 0: Error: ENC\nReaction: RESET\n\nCause:\n Error in encoder interface\n\nRemedy:\n Check connection of encoder, cable type\n and parameter setting 1: Error: ENC\nReaction: RESET\n\nCause:\n Error in encoder interface:\n Identified breaking wire of tracksignal\n\nRemedy:\n 1. Check contact of encoder cable (motor/device)\n 2. Check encoder cable\n 3. Check cable type and parameter of encoder 123: Error: ENC\nReaction: RESET\n\nCause:\n Error in initialization of Hiperface-interface\n of encoder G6/G7:\n Encoder signals communication error\n\nRemedy:\n Check wiring and parameter setting 124: Error: ENC\nReaction: RESET\n\nCause:\n Error in initialization of Hiperface-interface\n of encoder G6/G7:\n Device signals communication error\n\nRemedy:\n Check wiring and parameter setting 125: Error: ENC\nReaction: RESET\n\nCause:\n Error in initialization of Hiperface-interface\n of encoder G6/G7:\n No support of encoder type with actual software\n\nRemedy:\n 1. Check type of encoder\n 2. Check software version 126: Error: ENC\nReaction: RESET\n\nCause:\n Error in initialization of Hiperface-interface\n of encoder G6/G7:\n Encoder signals malfunction (Detailed information: parameter 402-HSTAT)\n\nRemedy:\n Check encoder 127: Error: ENC\nReaction: RESET\n\nCause:\n Error in initialization of Hiperface-interface\n of encoder G6/G7:\n Communication parameter not found\n\nRemedy:\n Check wiring and parameter setting 129: Error: ENC\nReaction: RESET\n\nCause:\n Error in initialization of Hiperface-interface\n of encoder G6/G7:\n Motor was moved during initialization\n\nRemedy:\n Take care of standstill of motor during initialization of Hiperface-interface\n of encoder [E31] 30: Error: TIM\nReaction: RESET\n\nCause:\n Control of running time (undefined routine) triggered\n\nRemedy:\n 1. Switch device off/on.\n 2. Pleaes contact your service provider if this error occurs again. 30: Error: TIM\nReaction: RESET\n\nCause:\n Control of 5 ms running time triggered\n\nRemedy:\n 1. Switch device off/on.\n 2. Please contact your service provider if this error occurs again. 41: Error: TIM\nReaction: RESET\n\nCause:\n Watchdog running time control (dSMC) triggered\n\nRemedy:\n 1. Switch device off/on.\n 2. Please contact your service provider if this error occurs again. [E32] 1: Error: FLW\n\nCause:\n Tracking error\n\nRemedy:\n 1. Reduce load or acceleration\n 2. Increase allowed tracking error [E33] 11: Error: WDG\n\nCause:\n Watchdog for RS232 (LustBus) triggered\n\nRemedy:\n 1. Check busmaster or increase 84-SWDGT [E34] 42: Error: VEC\nReaction: RESET\n\nCause:\n Error in initialization of dSMC-data-RAM\n\nRemedy:\n 1. Switch device off/on.\n 2. Please contact your service provider if this error occurs again. 43: Error: VEC\nReaction: RESET\n\nCause:\n Error in initialization of dSMC-program-RAM\n\nRemedy:\n 1. Switch device off/on.\n 2. Please contact your service provider if this error occurs again. [E35] 1: Error: BRK\n\nCause:\n Error at output OSD03: \n 1. Breaked cable (I < 150 mA)\n 2. Kurzschluß\n 3. Short circuit\n\nRemedy:\n 1. Check wiring\n 2. Check load (Imin = 150 mA, Imax = 2,0 A)\n 3. Check voltage supply [E36] 0: Error: POS\n\nCause:\n Error in positioning and process control\n Please contact your service provider 210: Error: POS\n\nCause:\n Positive hardware endswitch starts in positioning 211: Error: POS\n\nCause:\n Negative hardware endswitch starts in positioning 212: Error: POS\n\nCause:\n Positive software endswitch starts in positioning 213: Error: POS\n\nCause:\n Negative software endswitch starts in positioning 214: Error: POS\n\nCause:\n Reference point not defined or found\n\nRemedy:\n 1. Check connection and position of reference cam\n 2. Check parameters of reference run 215: Error: POS\n\nCause:\n Error in access to optional hardware\n\nRemedy:\n Check contact and parameters of optional hardware 216: Error: POS\n\nCause:\n Error in positioning and process control:\n Selected program not yet available\n\nRemedy:\n Check parameter of program selection 217: Error: POS\n\nCause:\n Error in positioning and process control:\n Jumps to an unavailable setnumber\n\nRemedy:\n Check syntax of program in process program editor 218: Error: POS\n\nCause:\n Error in positioning and process control:\n Called sub-program not available\n\nRemedy:\n Check syntax of program in process program editor 219: Error: POS\n\nCause:\n Target position is outside of positioning range\n\nRemedy:\n 1. Check positioning range\n 2. Check adjustment of endswitches 220: Error: POS\n\nCause:\n Error in positioning and process control:\n Division by zero 221: Error: POS\n\nCause:\n Error in positioning and process control:\n Max. nesting depth (10) exceeded\n\nRemedy:\n Check syntax of programm in process program editor 223: Error: POS\n\nCause:\n Target position not reached\n\nRemedy:\n 1. Check positioning range\n 2. Check load\n 3. Check positioning window (axis in position) 224: Error: POS\n\nCause:\n Loss of enabling advance travel\n\nRemedy:\n 1. Set enable advance travel, (if parameter set)\n 2. Control released 225: Error: POS\n\nCause:\n Do not activate (automatic/reference run/inching mode), \n Conflict of control location 226: Error: POS\n\nCause:\n Error in positioning and process control\n Index overflow (indicate addressing)\n\nRemedy:\n Check syntax of program in process program editor 232: Error: POS\n\nCause:\n Error in positioning and process control:\n Error in reading parameter\n 1. Reading failed or \n 2. the parameter is not readable\n\nRemedy:\n Check validity of parameter (number, value, access condition) 233: Error: POS\n\nCause:\n Error in positioning and process control:\n Error in writing a parameter\n 1. Writing failed or\n 2. the parameter is not writable\n\nRemedy:\n Check validity of parameter (number, value, access condition) 234: Error: POS\n\nCause:\n Error in processing a touchprobe process order 235: Error: POS\n\nCause:\n Error in positioning and process control:\n Order during axis movement not allowed (e.g. SAVE)\n\nRemedy:\n Wait for axis standstill or deactivation of control 236: Error: POS\n\nCause:\n Hardware endswitch interchanged\n\nRemedy:\n Correction of wiring endswitches or configuration \n of inputs of CDD3000 according to the suppression. [E37] 50: Error: FLH\nReaction: RESET\n\nCause:\n Error in data-flash-memory:\n TimeOut in delete process\n\nRemedy:\n 1. Switch device off/on.\n 2. Please contact your service provider if this error occurs again. 51: Error: FLH\nReaction: RESET\n\nCause:\n Error in data-flash-memory:\n One sector defect, writing failed\n\nRemedy:\n 1. Switch device off/on.\n 2. Please contact your service provider if this error occurs again. 57: Error: FLH\nReaction: RESET\n\nCause:\n Error in data-flash-memory:\n Identified faulty sector in start-up phase\n\nRemedy:\n 1. Reset device to factory setting\n 2. Switch device off/on.\n 3. Please contact your service provider if this error occurs again. [E38] 45: Error: HW\n\nCause:\n Left hardware endswitch starts 46: Error: HW\n\nCause:\n Right hardware endswitch starts [E39] 47: Error: HWE\n\nCause:\n Hardware endswitch interchanged\n\nRemedy:\n Correction of endswitch wiring or configuration\n of CDD3000 inputs according to suppression. [E40] 0: Warning: WRN\n\nCause:\n Signal warning not defined.\n Please contact your service provider. 59: Warning: WRN\n\nCause:\n The adjusted max. torque (parameter TCMMX, function msk limit values)\n is larger than the maximum rtorque, can be reached with the motor or device.\n\nPlease note:\n The max. torque was suited automatically.\n Check the new adjustment. 60: Warning: WRN\n\nCause:\n While initialisation of field modell motor data check has failed \n Please check motor data: \n Main inductivity is too large for device ? \n Motor current much smaller than device current ? \n 61: Warning: WRN\n\nCause:\n The position reference exceeds in connection with\n your distance scaling the allowed value range.\n\nPlease note:\n The maximum position range was limited automatically.\n Check the scaling (function mask basic setting scale)\n or the selected position reference. 62: Warning: WRN\n\nCause:\n The set maximum speed (parameter SCSMX, function mask limit values)\n is larger than the maximum speed, reached with the motor.\n\nPlease note:\n The max. speed was suited automatically.\n Check the new adjustment. 63: Warning: WRN\n\nCause:\n The selected positioning speed or acceleration exceeds\n in connection with your scaling the allowed value range.\n\nPlease note:\n Speed resp. accelereation was limited automatically.\n Check your scaling (function mask basic setting scale)\n or the selected speed resp. acceleration. 80: Warnung: WRN\n\nCause:\n Warning in execution of a customer specific software function 81: Warnung: WRN\n\nCause:\n Warning in execution of a customer specific software function