NAVIGATION: Motion profile > Homing mode > Homing methods > Homing methods 17-30: Reference cam

Homing methods 17-30: Reference cam

Method 17-30

The homing method types 17 to 30 are equivalent to types 1 to 14.
Definition of the reference point is independent of the zero pulse. It depends only on the cam or on the limit switches.

Bild: Homing methods 17 to 30 are equivalent to methods 1 to 14


Method 1 corresponds to method 17 Definition of the reference point is independent of the zero pulse.
It depends only on the cam or on the limit switches.
Method 4 corresponds to method 20
Method 8 corresponds to method 24
Method 12 corresponds to method 28
Method 14 corresponds to method 30

Tabelle: Comparison of homing methods