P 1318 MPRO_ECAM_ControlWord.
Bit number | Function | iPLC function |
---|---|---|
0-7 | Start segment (8-bit value) | - |
8-15 | Reserve | - |
16 | Absolute (true) / relative (false) master relationship | - |
17 | Absolute (true) / relative (false) master (CAM) relationship at cam in | - |
18 | Absolute (true) / relative (false) slave (CAM) relationship at cam in | - |
19-23 | Reserve | - |
24 | Change gear ratio of the electronic gear online | MCB_GearRatioChange |
25 | Disable master calculation | MCB_Cam_MasterEnable |
26 | Enable master calculation | MCB_Cam_MasterEnable |
27 | Select CAM table | MCB_CamTableSelect |
28 | Start Ecam | MCB_CamIn |
29 | Stop Ecam | MCB_CamOut |
30 | Start Egear | MCB_GearIn |
31 | Stop Egear | MCB_GearOut |
Tabelle: Control word ECAM
P 1326 MPRO_ECAM_StatusWord
Bit number | Description |
---|---|
0-7 | Actual segment (8-bit value) |
8-11 |
Actual ECAM / EGEAR state machine state (4-bit value) 0: ECAM / EGEAR asynchronous 1: ECAM / EGEAR synchronous 2: ECAM / EGEAR synchronizing 3: ECAM / EGEAR desynchronizing 4: ECAM / EGEAR active and waiting for going asynchronous 5: ECAM / EGEAR inactive and waiting for going synchronous |
12-26 | Reserve |
27 | ECAM / EGEAR is active |
28 | Valid segments chosen |
29 | Master data are valid |
30 | Master is initialized |
31 | Master calculation is active |
Tabelle: Status word ECAM
Copyright © LTi DRiVES GmbH, Januar 2013, ID-Nr.: 0842.26B.1-00 DE