NAVIGATION: Motion profile > Synchronized movement > Electronic_gearing > Master configuration

Master configuration

Specifying the master encoder:


The master encoder may be a "virtual master", a higher-level PLC, or an encoder system. The channels for the encoder system to be used are selected from the list box. Channel 3 is only available if an external interface X8 (option module) is present. If a higher-level PLC is used as the master encoder P 1319 MPRO_ECAM_CamMaster_Axis_Type = PARA(2), the resolution must be set referred to one motor revolution
P 0250 MPRO_ECAM_PARAMaster_Amplitude.



Bild: Master configuration Channel selection



Parameters

P. no.

Parameter name

Setting

Function
P1319 MPRO_ECAM_CamMaster_AxisType Selection of master encoder
(0) No Axis Master encoder selected
(1) Virtual Master Virtual master
(2) PARA

Parameter interface

(3) ENC CH1 Encoder on channel 1
(4) ENC CH2 Encoder on channel 2
(5) ENC CH3 Encoder on channel 3

Tabelle: Channel selection



Anti-reverse mode

Anti-reverse mode.htm

P. no.

Parameter name

Setting

Function
P1320 MPRO_ECAM_CamMaster_RevLockMode Anti-reverse mode
(0) INACTIVE Anti-reverse mode inactive
(1) ACTIVE with waycompensation Anti-reverse mode with path compensation:
While the slave accelerates to the speed of the master during engagement, the master and slave do not move synchronously. To catch up the advancing master, select the "path-compensated" function.
(2) ACTIVE without waycompensation

Anti-reverse mode without path compensation

Tabelle: Anti-reverse mode setting


Filter type for guide value

When using a real master encoder, encoder signals may be subject to noise. The signals can be filtered with a PT1 element or a mean value filter


.

Bild: Selection window for filter


Parameters

P. no. Parameter name Setting Function
P1340 MPRO_ECAM_CamMaster_SpeedFilTyp Selection of filter type
(0) OFF Not active
(1) PT1 PT1 Filter
(2) AVG Mean value filter

Tabelle: Selection of a suitable filter for noise suppression



Speed

The master encoder can be assigned an additional speed factor.



Bild: Speed factor input window



Parameter Master

When using the "Parameter Master", the number of increments per motor revolution P 0250 MPRO_ECAM_ParaMaster_Amplitude must be set.




Siehe \"Anti-reverse mode"\